ET0350
- Pitch
35 mm - Height
31 mm - Width
50 mm - Bending radius
48 – 125 mm
Stay variants
Design 030
Frame with lamella crossbars in the outer radius
- Weight-optimized plastic frame with particularly high torsional rigidity.
- Swivable slats on one side in any position.
Opening options
outside: Swivable.
Design 040
Frame with lamella crossbars in the inner radius
- Weight-optimized plastic frame with particularly high torsional rigidity.
- Swivable slats on one side in any position.
Opening options
inside: Swivable.
Unsupported arrangement
Dynamics of unsupported arrangement | t [mm] |
|
vmax [m/s] | amax [m/s2] | |
5 | 20 | 35 |
Installation dimensions unsupported
KR [mm] |
H [mm] |
Hz [mm] |
LB [mm] |
UB [mm] |
48 | 146 | 176 | 220 | 103 |
60 | 170 | 200 | 258 | 115 |
75 | 200 | 230 | 306 | 130 |
100 | 250 | 280 | 384 | 155 |
125 | 300 | 330 | 463 | 180 |
Load diagram
for unsupported length depending on additional load
- Intrinsic cable carrier weight qk = 0.2 kg/m with Bi 16 mm.
For other inner widths the maximum additional load changes. - Fixed point offset Lv: For off-center fixed point connections please contact us.
Calculating the cable carrier length
- Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)
- Unsupported length Lf: Lf = LS/2 + t
End Connectors
One part end connectors – plastic (suitable for Bi 25 – 50)
The plastic end connectors can be connected from above or below. The connection type can be changed by reconnecting the end connector.
Bi [mm] |
BK [mm] |
nz [mm] |
50 | 62 | 6 |
The end connectors are also available as an option without strain relief comb. Please state when ordering.
Connection variants
Connection point
F – fixed point
M – driver
Connection type
A – threaded joint outside (standard)
I – threaded joint inside
Subject to change.