ET1455
- Pitch
45.5 mm - Height
25 mm - Width
78 mm - Bending radius
52 – 200 mm
Stay variants
Design 030
Frame with lamella crossbars in the outer radius
- Weight-optimized plastic frame with particularly high torsional rigidity.
- Swivable slats on one side in any position.
Opening options
outside: Swivable.
Design 040
Frame with lamella crossbars in the inner radius
- Weight-optimized plastic frame with particularly high torsional rigidity.
- Swivable slats on one side in any position.
Opening options
inside: Swivable.
Unsupported arrangement
Dynamics of unsupported arrangement | t [mm] |
|
vmax [m/s] | amax [m/s] | |
10 | 50 | 45.5 |
Installation dimensions unsupported
KR [mm] |
H [mm] |
Hz [mm] |
LB [mm] |
UB [mm] |
52 | 140 | 165 | 255 | 116 |
65 | 166 | 191 | 296 | 129 |
95 | 226 | 251 | 390 | 159 |
125 | 286 | 211 | 484 | 189 |
150 | 336 | 361 | 563 | 214 |
180 | 396 | 421 | 657 | 244 |
200 | 436 | 461 | 720 | 264 |
Load diagram
for unsupported length depending on additional load
- Intrinsic cable carrier weight qk = 0.75 kg/m with Bi 38 mm.
For other inner widths the maximum additional load changes. - Fixed point offset Lv: For off-center fixed point connections please contact us.
Calculating the cable carrier length
- Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)
- Unsupported length Lf: Lf = LS/2 + t
Gliding arrangement
Dynamics of gliding arrangement | t [mm] |
|
vmax [m/s] | amax [m/s2] | |
2,5 | 20 | 45.5 |
- For more information on gliding arrangement please contact us.
- Only design 030 may be used for gliding arrangements.
- The gliding cable carrier has to be routed in a channel.
Our engineers will be happy to help with project planning – please contact us.
Calculating the cable carrier length
- Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)
End Connectors
One part end connectors – plastic
The plastic end connectors can be connected from above and below. The connection type can be changed by reconnecting the end connector.
Bi [mm] |
BEF [mm] |
nz [mm] |
78 | 94 | 2 x 6 |
- Recommended tightening torque: 6 Nm for screws M6 - 8.8
The end connectors are optionally also available without strain relief comb (except Bi 25). Please state when ordering.
Connection variants
Connection point
F – fixed point
M – driver
Connection type
A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint outside rotated by 90°
K – threaded joint inside rotated by 90°
Subject to change.