P0240
- Pitch
24 mm - Height
20 mm - Width
20 – 40 mm - Bending
radius
27 – 72 mm
Stay variants
Design 010
Frame with crossbars in the outer radius
- Belt with push-in side parts.
Opening options
outside: can be pressed inwards.
Unsupported arrangement
Dynamics of unsupported arrangement | t
[mm] |
|
vmax [m/s] | amax [m/s2] | |
25 | 200 | 24 |
Installation dimensions unsupported
KR
[mm] |
H
[mm] |
Hz
[mm] |
LB
[mm] |
UB
[mm] |
27 | 106 | 126 | 133 | 77 |
42 | 136 | 156 | 180 | 92 |
57 | 166 | 186 | 227 | 107 |
72 | 196 | 216 | 275 | 122 |
Load diagram
for unsupported length depending on additional load
- Intrinsic cable carrier weight qk = 0,27 kg/m at Bi 40 mm.
For other inner widths the maximum additional load changes. - Fixed point offset Lv: For off-center fixed point connections please contact us.
Calculating the cable carrier length
- Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)
- Unsupported length Lf: Lf = LS/2 + t
End Connectors
One part end connectors – plastic (with integrated strain relief)
The plastic end connectors can be connected from above or from below. The correct end connector has to be selected in each case.
Bi
[mm] |
BA
[mm] |
nZ
[mm] |
20 | 11 | 2 |
30 | 22 | 3 |
40 | 32 | 3 |
- The end connectors
cannot be swiveled.
Connection variants
Connection point
F – fixed point
M – driver
Connection type
A – threaded joint outside (standard)
I – threaded joint inside
Subject to change.