UA1320

  • Pitch
    32 mm
  • Height
    20 mm
  • Width
    15 – 65 mm
  • Bending
    radius

    28 – 125 mm

Stay variants

Design 020

Closed frame

  • Weight-optimized, closed plastic frame with particularly high torsional rigidity.

Opening options
outside/inside: Closed.

more information

Stay variant

Unsupported arrangement

Unsupported arrangement
Dynamics of unsupported arrangement t
[mm]
vmax [m/s] amax [m/s2]
10 50 32

Installation dimensions unsupported

KR
[mm]
H
[mm]
Hz
[mm]
LB
[mm]
UB
[mm]
28 81.5 98.5 152 73
38 101.5 118.5 184 83
48 121.5 138.5 215 93
75 175.5 192.5 300 120
100 225.5 242.5 379 145
125 275.5 292.5 457 170

Load diagram

for unsupported length depending on additional load

Load diagram
  • Intrinsic cable carrier weight qk = 0.40 kg/m with Bi 50 mm. For other inner widths the maximum additional load changes.
  • Fixed point offset Lv: For off-center fixed point connections please contact us.

Calculating the cable carrier length

  • Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)
  • Unsupported length Lf: Lf = LS/2 + t

End connectors

One part end connectors – plastic (with integrated strain relief)

The plastic end connectors can be connected from above or below. The connection type can be changed by turning the end connector.

One part end connectors – plastic (with integrated strain relief)
Bi
[mm]
BEF
[mm]
nz
15 27 2
25 37 3
38 50 4
50 62 5
65 77 6
  • The end connectors cannot be swiveled.
End connector

The end connectors are also available as an option without integrated strain relief. Please state when ordering.

Connection variants

Connection variants

Connection point
F – fixed point
M – driver

Connection type
A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint, rotated through 90° to the outside
K – threaded joint, rotated through 90° to the inside

Subject to change.