M0320

  • Pitch
    32 mm
  • Height
    19 mm
  • Width
    25 – 280 mm
  • Bending
    radius

    37 – 200 mm

Stay variants

Aluminum stay 01

Frame stay detachable inside

  • Space-saving, quick to open and close.
  • Aluminum profile bars for light to medium loads. Assembly without screws.
  • Available customized in 1 mm width sections.

Opening options
inside: Release by turning by 90°.

more information

Stay variant

Aluminum stay 02

Frame stay detachable outside “the standard”

  • Space-saving, quick to open and close.
  • Aluminum profile bars for light to medium loads. Assembly without screws.
  • Available customized in 1 mm width sections.

Opening options
outside: Release by turning by 90°.

more information

Stay variant

Plastic stay RE

Frame screw-in stay

  • Plastic profile bars for light to medium loads. Assembly without screws.
  • Available customized in 4 mm width sections.

Opening options
outside/inside: Release by turning by 90°.

more information

Stay variant

Unsupported arrangement

Unsupported arrangement
Dynamics of unsupported arrangement t
[mm]
vmax [m/s] amax [m/s2]
10 50 32

Installation dimensions unsupported

KR
[mm]
H
[mm]
Hz
[mm]
LB
[mm]
UB
[mm]
37 101.5 121.5 181 83
47 121.5 141.5 212 93
77 181.5 201.5 306 123
100 227.5 247.5 379 146
200 427.5 427.5 693 246

Load diagram

for unsupported length depending on additional load

Load diagram
  • Intrinsic cable carrier weight qk = 0.54 kg/m. The maximum additional load decreases if this value is exceeded.
  • Fixed point offset Lv: For off-center fixed point connections please contact us.

Calculating the cable carrier length

  • Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)
  • Unsupported length Lf: Lf = LS/2 + t

Gliding arrangement

Gliding arrangement
Dynamics of gliding arrangement t
[mm]
vmax [m/s] amax [m/s2]
2.5 25 32
  • For more information on gliding arrangement please contact us.
  • The gliding cable carrier has to be routed in a channel. Our engineers will be happy to help with project planning – please contact us.

Calculating the cable carrier length

  • Cable carrier length Lk: Lk ≈ LS/2 + LB (Cable carrier length Lk rounded to pitch t)

End connectors

One part end connectors – plastic/aluminum (with integrated strain relief)

The plastic/aluminum end connectors can be connected from above and below. The connection variants on the fixed point and on the driver can be combined and, if required, changed subsequently.

One part end connectors – plastic/aluminum (with integrated strain relief)
Bi
[mm]
BEF
[mm]
nz
25 36 2
29 40 2
37 48 3
39 50 4
49 60 4
69 80 5
89 100 7
109 120 8
124 135 10
149 160 11
  • Cable carrier widths deviating from the clear cable carrier widths Bi are supplied with end connectors without strain relief as a standard.
Connection variants

Connection variants

Connection point
F – fixed point
M – driver

Connection type
A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint outside rotated by 90°
K – threaded joint inside rotated by 90°

One part end connectors – plastic/aluminum

The plastic/aluminum end connectors can be connected from above and below. The connection variants on the fixed point and on the driver can be combined and, if required, changed subsequently.

One part end connectors – plastic/aluminum
Connection variants

Connection variants

Connection point
F – fixed point
M – driver

Connection type
A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint outside rotated by 90°
K – threaded joint inside rotated by 90°

Subject to change.