TRAXLINE DATA 700 TPi CD / POWER 700 TPi CD   1 kV

Double-shielded continuous bending hi-flex PUR data cables

Picture obtainable.

Core insulation
KS-PP

stranded in pairs

Pair shield
continuous bending hi-flex,
tin-plated braided copper shield

Inner jacket
KS-TPE

valley-sealed,
pressure extruded,
hi-flex design

Overall shield
continuous bending hi-flex, tin-plated copper braiding for smallest bend radii

Outer jacket
KS-PUR

pressure extruded,
hi-flex design,
extremely abrasion-resistant

Jacket colour black
ozone-resistant,
UV-resistant

Developed for:

  • measurement and control equipment
  • sensor equipment
  • data and signal cables
  • extremely heavy loads

Properties:

  • hi-flex design
  • metermarked
  • oil-resistant
  • CFC-free
  • UV-resistant
  • silicone-free
  • RoHS-conform
  • flame-retardant
  • halogen-free
  • ozone-resistant

More than
7 million
motion cycles!

Up to
500 m
travel length!

 

Design

Conductor:

conductors class 6 of bare copper wires in an optimized hi-flex design

Center element:

type-optimized

Core insulation:

KS-PP

Core identification:

according to DIN 47100
article number 45669, 45679: black with white numbers

Core stranding:

cores bundled in pairs in short pitches with minimal torsion

Inner jacket pairs:

KS-TPE

Inner jacket:

KS-TPE

Shielding:

coverage nom. 85 %

Outer jacket:

KS-PUR

Jacket color:

black

Technical Data

Temperature range while moved:

- 30  to  + 90 °C

Minimum bend radius while moved:

KRmin ≥ 7.5 x Ø

vmax supported:

20 m/s

vmax gliding:

5 m/s

amax:

50 m/s²

Insulation resistance:

≥ 30 MΩ x km

Rated voltage:

according to VDE 300/300 V
according to UL 300 V
part number 45668, 45669, 45679:
according to VDE 0.6/1 kV
according to UL 1 kV

Approvals:

cURus, based on VDE

varying parameters possible – please contact us

CE

Types

 

TRAXLINE DATA 700 TPi CD – double-shielded

core number x nominal-cross-section
in mm²

part
number

max. Ø mm

cable weight
kg/m

copper weight
kg/m

(3 x (2 x 0.252))

45661

13.1

0.212

0.077

(4 x (2 x 0.52))

45662

15.4

0.310

0.158

(10 x (2 x 0.52))

45664

26.1

0.970

0.335

(16 x (2 x 0.52))

45665

27.5

1.280

0.632


 

TRAXLINE POWER 700 TPi CD – 1 kV – double-shielded

core number x nominal-cross-section
in mm²

part
number

max.
OD
in mm

cable weight
kg/m

copper weight
kg/m

(2 x (2 x 1.52))

45667

19.4

0.460

0.194

(6 x (2 x 1.52))

45669

27.0

0.928

0.437

(10 x (2 x 1.52))

45679

37.5

1.771

0.803



Additional cable types upon request.